2. Installation
RuggedCom® RuggedSwitch® 14 M2100 Installation Guide Rev 1.0
When equipped with two HI voltage power supplies, independent AC sources can be
used to power the product for greater redundancy.
2.2.2. DC Power Supply Wiring Examples
+
Figure 2.6. DC Single Power
Supply Wiring Example
+
+
Figure 2.7. DC Dual Redundant
Power Supply Wiring Example
88-300 VDC rated equipment: A 300 VDC appropriately rated circuit breaker must be
installed.
A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
For dual DC power supplies, Separate circuit breakers must be installed and separately
identified.
Equipment must be installed according to the applicable country wiring codes.